GE Profile™ GEOSPRING™ Hybrid Heat Pump Water Heater - Installation Requirements
Below are some general installation considerations for the GE Profile™ GEOSPRING™ Hybrid Heat Pump Water Heater. The Installation Instructions for your water heater provides more detailed requirements for Location, Clearances, Power Requirements, Plumbing, etc. This is your best resources for making preparations before installing the water heater, as well as the actual installation process itself.
Download a copy of your Owner's Manual and Installation Instructions for your water heater.
Location
Don't install the water heater in outdoor, unprotected areas. Protect your water heater and water lines from freezing temperatures and high corrosive atmospheres.
Locate the water heater in a clean, dry area as close as practical to where there's the greatest demand for heated water. Long, uninsulated hot water lines can waste energy and water.
Clearances
The GEOSPRING™ hybrid water heater draws in air from the room to heat the water. As a result, the room must be at least 10' x 10' x 7' (700 cubic feet) or larger. If the room is smaller, there must be a louvered door or two louvered sections (one at the top and one at the bottom of the door/wall) for airflow. Each of these vents should have at least 240 square inches of open airflow area. Alternatively, you can use a GE Appliances PH10VK Ducting Kit in small areas.